Schmitz, Henning ORCID: 0000-0001-6143-1187, Rabe, Moritz ORCID: 0000-0002-7085-4066, Janssens, Guillaume ORCID: 0000-0001-9553-6024, Bondesson, David ORCID: 0000-0003-3112-886X, Rit, Simon ORCID: 0000-0003-2530-1013, Parodi, Katia ORCID: 0000-0001-7779-6690, Belka, Claus, Dinkel, Julien, Kurz, Christopher, Kamp, Florian and Landry, Guillaume (2021). Validation of proton dose calculation on scatter corrected 4D cone beam computed tomography using a porcine lung phantom. Phys. Med. Biol., 66 (17). BRISTOL: IOP PUBLISHING LTD. ISSN 1361-6560
Full text not available from this repository.Abstract
Proton therapy treatment for lungs remains challenging as images enabling the detection of inter- and intra-fractional motion, which could be used for proton dose adaptation, are not readily available. 4D computed tomography (4DCT) provides high image quality but is rarely available in-room, while in-room 4D cone beam computed tomography (4DCBCT) suffers from image quality limitations stemming mostly from scatter detection. This study investigated the feasibility of using virtual 4D computed tomography (4DvCT) as a prior for a phase-per-phase scatter correction algorithm yielding a 4D scatter corrected cone beam computed tomography image (4DCBCT(cor)), which can be used for proton dose calculation. 4DCT and 4DCBCT scans of a porcine lung phantom, which generated reproducible ventilation, were acquired with matching breathing patterns. Diffeomorphic Morphons, a deformable image registration algorithm, was used to register the mid-position 4DCT to the mid-position 4DCBCT and yield a 4DvCT. The 4DCBCT was reconstructed using motion-aware reconstruction based on spatial and temporal regularization (MA-ROOSTER). Successively for each phase, digitally reconstructed radiographs of the 4DvCT, simulated without scatter, were exploited to correct scatter in the corresponding CBCT projections. The 4DCBCT(cor) was then reconstructed with MA-ROOSTER using the corrected CBCT projections and the same settings and deformation vector fields as those already used for reconstructing the 4DCBCT. The 4DCBCT(cor) and the 4DvCT were evaluated phase-by-phase, performing proton dose calculations and comparison to those of a ground truth 4DCT by means of dose-volume-histograms (DVH) and gamma pass-rates (PR). For accumulated doses, DVH parameters deviated by at most 1.7% in the 4DvCT and 2.0% in the 4DCBCT(cor) case. The gamma PR for a (2%, 2 mm) criterion with 10% threshold were at least 93.2% (4DvCT) and 94.2% (4DCBCT(cor)), respectively. The 4DCBCT(cor) technique enabled accurate proton dose calculation, which indicates the potential for applicability to clinical 4DCBCT scans.
Item Type: | Journal Article | ||||||||||||||||||||||||||||||||||||||||||||||||
Creators: |
|
||||||||||||||||||||||||||||||||||||||||||||||||
URN: | urn:nbn:de:hbz:38-595913 | ||||||||||||||||||||||||||||||||||||||||||||||||
DOI: | 10.1088/1361-6560/ac16e9 | ||||||||||||||||||||||||||||||||||||||||||||||||
Journal or Publication Title: | Phys. Med. Biol. | ||||||||||||||||||||||||||||||||||||||||||||||||
Volume: | 66 | ||||||||||||||||||||||||||||||||||||||||||||||||
Number: | 17 | ||||||||||||||||||||||||||||||||||||||||||||||||
Date: | 2021 | ||||||||||||||||||||||||||||||||||||||||||||||||
Publisher: | IOP PUBLISHING LTD | ||||||||||||||||||||||||||||||||||||||||||||||||
Place of Publication: | BRISTOL | ||||||||||||||||||||||||||||||||||||||||||||||||
ISSN: | 1361-6560 | ||||||||||||||||||||||||||||||||||||||||||||||||
Language: | English | ||||||||||||||||||||||||||||||||||||||||||||||||
Faculty: | Unspecified | ||||||||||||||||||||||||||||||||||||||||||||||||
Divisions: | Unspecified | ||||||||||||||||||||||||||||||||||||||||||||||||
Subjects: | no entry | ||||||||||||||||||||||||||||||||||||||||||||||||
Uncontrolled Keywords: |
|
||||||||||||||||||||||||||||||||||||||||||||||||
URI: | http://kups.ub.uni-koeln.de/id/eprint/59591 |
Downloads
Downloads per month over past year
Altmetric
Export
Actions (login required)
View Item |