Goertz, Lukas
ORCID: 0000-0002-2620-7611, Al-Sewaidi, Yosef, Habib, Mahmoud, Zopfs, David
ORCID: 0000-0001-9978-7453, Reichardt, Benjamin, Ranft, Alexander and Kabbasch, Christoph
ORCID: 0000-0003-3712-2258
(2024).
State-of-the-art mobile head CT scanner delivers nearly the same image quality as a conventional stationary CT scanner.
Scientific Reports, 14 (1).
pp. 1-9.
Springer Nature.
ISSN 2045-2322
|
PDF
s41598-024-56089-z.pdf Bereitstellung unter der CC-Lizenz: Creative Commons Attribution. Download (1MB) |
Abstract
[Artikel-Nr.: 6393] The use of mobile head CT scanners in the neurointensive care unit (NICU) saves time for patients and NICU staff and can reduce transport‑related mishaps, but the reduced image quality of previous mobile scanners has prevented their widespread clinical use. This study compares the image quality of SOMATOM On.Site (Siemens Healthineers, Erlangen, Germany), a state‑of‑the‑art mobile head CT scanner, and a conventional 64‑slice stationary CT scanner. The study included 40 patients who underwent head scans with both mobile and stationary scanners. Gray and white matter signal and noise were measured at predefined locations on axial slices, and signal‑to‑noise ratios (SNRs) and contrast‑to‑noise ratios (CNRs) were calculated. Artifacts below the cranial calvaria and in the posterior fossa were also measured. In addition, image quality was subjectively assessed by two radiologists in terms of corticomedullary differentiation, subcalvarial space, skull artifacts, and image noise. Quantitative measurements showed significantly higher image quality of the stationary CT scanner in terms of noise, SNR and CNR of gray and white matter. Artifacts measured in the posterior fossa were higher with the mobile CT scanner, but subcalvarial artifacts were comparable. Subjective image quality was rated similarly by two radiologists for both scanners in all domains except image noise, which was better for stationary CT scans. The image quality of the SOMATOM On.Site for brain scans is inferior to that of the conventional stationary scanner, but appears to be adequate for daily use in a clinical setting based on subjective ratings.
| Item Type: | Article |
| Creators: | Creators Email ORCID ORCID Put Code Al-Sewaidi, Yosef UNSPECIFIED UNSPECIFIED UNSPECIFIED Habib, Mahmoud UNSPECIFIED UNSPECIFIED UNSPECIFIED Reichardt, Benjamin UNSPECIFIED UNSPECIFIED UNSPECIFIED Ranft, Alexander UNSPECIFIED UNSPECIFIED UNSPECIFIED |
| URN: | urn:nbn:de:hbz:38-815270 |
| Identification Number: | 10.1038/s41598-024-56089-z |
| Journal or Publication Title: | Scientific Reports |
| Volume: | 14 |
| Number: | 1 |
| Page Range: | pp. 1-9 |
| Number of Pages: | 9 |
| Date: | 16 March 2024 |
| Publisher: | Springer Nature |
| ISSN: | 2045-2322 |
| Language: | English |
| Faculty: | Faculty of Medicine |
| Divisions: | Faculty of Medicine > Radiologische Diagnostik > Institut und Poliklinik für Radiologische Diagnostik |
| Subjects: | Medical sciences Medicine |
| Uncontrolled Keywords: | Keywords Language Computed tomography ; ICU ; Intracranial haemorrhage ; Mobile CT English |
| ['eprint_fieldname_oa_funders' not defined]: | Publikationsfonds UzK |
| Refereed: | Yes |
| URI: | http://kups.ub.uni-koeln.de/id/eprint/81527 |
Downloads
Downloads per month over past year
Altmetric
Export
Actions (login required)
![]() |
View Item |
https://orcid.org/0000-0002-2620-7611